Clean room

A room in which the concentration of dust in the air, temperature, humidity and pressure are strictly controlled to ensure a high level of cleanliness. As the level of contamination from foreign substances during the manufacture of electrical equipment and components (semiconductors) must not exceed certain ppm values, production must take place in a cleanroom. The US standard FED-STD-209E (replaced by ISO 14644-1) defines cleanroom conditions as follows:

Cleanroom class Maximum number of dust particles larger than 0.5 µm per ft³ (per l) Maximum number of dust particles larger than 5 µm per ft³ (per l)
100 100 (3.5)
10,000 10,000 (350) 65 (2.3)
100,000 100,000 (3,500) 700 (25)
Cleanroom class according to

ISO 14644-1 Maximum concentration of dust particles up to 0.5 µm in particles per m³ Maximum concentration of dust particles up to 5 µm in particles per m³
100 – ISO 5 3,520 29
10,000 – ISO 7 352,000 2,930
100,000 – ISO 8 3,520,000 29,300